Violation Detail
Standard Cited: 19100421 G Pre-dive procedures.
Inspection Nr: 980215.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 12/09/2014
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/15/2014
Gravity: 10
Report ID: 0418800
Contest Date: 01/02/2015
Final Order: 09/02/2015
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 09/02/2015 | $7,000.00 | 12/15/2014 | Serious | |
| Penalty | C: Contested | 01/08/2015 | $7,000.00 | 12/15/2014 | Serious | |
| Penalty | Z: Issued | 12/09/2014 | $7,000.00 | 12/15/2014 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.421(g): The breathing gas supply system, including reserve breathing gas supplies, masks, helmets, thermal protection, and bell handling mechanism (when appropriate), were not inspected prior to each dive: On or about June 10, 2014, at the above addressed dive site, the employer did not inspect the air compressor, filters, or regulator prior to each dive.
Translate