Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 962660.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $4,900.00
Issuance Date: 05/28/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/21/2014
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 06/20/2014
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/20/2014 | $4,900.00 | 07/21/2014 | Serious | |
| Penalty | Z: Issued | 05/28/2014 | $7,000.00 | 06/09/2014 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(d)(1): Pulleys that are 7' or less from the floor or working platform, shall be guarded in accordance with the standards specified in (m) and (o) of the section: Employees were exposed to injuries at fence machine 201 because the pulleys approximately 49 inches and 79 inches from the floor were not completely enclosed with a guard.