Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 709899.015
Citation: 01005A
Citation Type: Serious
Abatement Date: 02/01/2013 2
Initial Penalty: $5,000.00
Current Penalty: $5,000.00
Issuance Date: 01/28/2013
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0111700
Contest Date:
Final Order: 02/21/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 02/22/2013 | $5,000.00 | 02/01/2013 | Serious | |
Penalty | F: Formal Settlement | 02/21/2013 | $5,000.00 | 02/01/2013 | Serious | |
Penalty | Z: Issued | 01/28/2013 | $5,000.00 | 02/01/2013 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Instance a. Site - The horizontal shaft on the Laminator # 3 was not adequately guarded on all sides to prevent employees from accidental contact during the rotation cycle. Instance b. Site - The horizontal shaft on the flipping machine was not adequately guarded on all sides to prevent employees from accidental contact during the rotation cycle.