Violation Detail
Standard Cited: 6A0001 General Duty Clause
Inspection Nr: 311211296
Citation: 01005A
Citation Type: Serious
Abatement Status: E
Initial Penalty: $3,500.00
Current Penalty:
Issuance Date: 05/03/2010
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 06/04/2010
Gravity: 10
Report ID: 0257260
Contest Date: 05/21/2010
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 04/26/2012 | 06/04/2010 | Serious | ||
| Penalty | Z: Issued | 05/03/2010 | $3,500.00 | 06/04/2010 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard: EXPLOSION
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: The NFPA 30 Flammable and Combustible Liquid Code 2008 Edition, is a Recognized Industry Standard of recommended practices, that provide fundamental safeguards for the storage, handling, and use of flammable and combustible liquids. a)Employees that worked at CAPECO performing routine task such as tank operator,waste treatment operator, loading rack operator, among others were exposed or could be exposed to flammable and combustible release, fire and or explosion. The employer has no Management of Change (MOC) for the installation and operation of tanks 409 and 107, which would have included the safety and health impacts of not installing an automatic tank overfilling system, the lack of formal written operating procedures for tank filling operations, or the development and implementation of maintenance procedures for tank level systems including the calibration of the tank level readings at the operators console, with the tank gauge levels and the actual levels contained in the tanks. b)No MOC from the change from those tanks systems that were originally installed with automatic overfill systems but due to maintenance issues with those system, CAPECO decided to use only unwritten operating procedures to control tank filling operations. Among other methods, one feasible and acceptable abatement method to correct this hazard is: 1.Follow NFPA 30 - 6.4.2 Management of Change. The hazards analysis shall be repeated whenever the hazards leading to fire or explosion change significantly. Conditions that might require repeating a review shall include, but are not limited to, the following: a.When changes occur in the materials in process. b.When changes occur in process equipment. c.When changes occur in process control. d.When changes occur in operating procedures or assignments. El codigo, NFPA 30 liquidos inflamable y combustible edicion 2008 es un reglamento de practicas reconocidas por la industria, que proporcionan las salvaguardiasfundamentales para el manejo, almacenaje, y uso de liquidos inflamables y combustibles. a)Empleados que trabajaban en CAPECO, realizando tareas rutinarias tales como operador de tanque, operador de tratamiento de aguas, operador de area de carga, entre otros fueron o podrian haber estado expuestos a liberacion de productos quimicos inflamables, combustible, fuego y/o explosion. El patrono no tenia el Manejo de Cambio (MOC) para la instalacion y operacion de los tanques 409 y 107, que habria incluido las consecuencias a la seguridad y a la salud por no instalar un sistema de sobre llenado automatico, la falta de procedimientos operacionales escritos formales para las operaciones de llenado de tanques, o el desarrollo e implementacion de procedimientos de mantenimiento para los sistemas de nivel de tanques incluyendo la calibracion de las lecturas del nivel de los tanques en las consola de los operadores con los indicadores de nivel de los tanques y los niveles reales que contenian los tanques. b)No se realizo MOC para aquellos tanques que debido a asuntos de mantenimiento se cambiaron de un sistema de sobrellenado automatico a uno no-automatico, donde utilizaron solo procedimientos de operacion no escritos para controlar las operaciones de llenado. Entre varios metodos, uno metodo de correccion aceptable y factibles para corregir este riesgo es: 1.Seguir el NFPA 30 6.4.2 Manejo de Cambio. El analisis de riesgo debe ser repetido en cualquier momento que los riesgos conducentes a fuego o explosion cambian significativamente. Condiciones que requieren repetir una revision deben incluir, pero no limitarse a lo siguiente: a.Cuando ocurren cambios en los materiales en el proceso. b.Cuando ocurren cambios en el equipo del proceso. c.Cuando ocurren cambios en el control del proceso. d.Cuando ocurren cambios en los procedimiento de operacion o tarea.ion
Translate