Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1765768.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,524.00
Current Penalty: $6,914.40
Issuance Date: 08/30/2024
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 05/01/2025
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 10/01/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 01/31/2025 | $6,914.40 | 05/01/2025 | Serious | |
Penalty | I: Informal Settlement | 10/01/2024 | $6,914.40 | 01/31/2025 | Serious | |
Penalty | Z: Issued | 08/30/2024 | $11,524.00 | 09/16/2024 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Basement and blender floor; On or about July 24, 2024, and dates prior, energy control (Lockout-Tagout) procedures were not developed/documented for the 6-ton mixer, blender, and AG-10 auger while employees performed cleaning operations.