Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1697373.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 03/06/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 04/01/2024
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 03/22/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/22/2024 | $16,131.00 | 04/01/2024 | Serious | |
Penalty | Z: Issued | 03/06/2024 | $16,131.00 | 04/01/2024 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about September 6, 2024, at the Inta-Roto (IR) Coater Slitter (Serial: 82M-COAT-01), employees performed maintenance activities including, but not limited to setting up and threading the slitter separator, without using machine specific energy control procedures.