Powered by GoogleTranslate

Violation Detail

Standard Cited: 19101000 A02 Air contaminants.

This violation item has been deleted.

Inspection Nr: 1679658.015

Citation: 01005A

Citation Type: Serious

Abatement Status:  

Initial Penalty: $15,625.00

Current Penalty: $0.00

Issuance Date: 12/08/2023

Nr Instances: 11

Nr Exposed: 4

Abatement Date: 01/29/2024

Gravity: 10

Report ID: 0418100

Contest Date: 01/03/2024

Final Order: 10/17/2024

Related Event Code (REC): C

Emphasis:

Substance: 1620

Substance: 1840

Substance: 9135


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 10/17/2024 $0.00 01/29/2024 Serious  
Penalty C: Contested 01/12/2024 $15,625.00 01/29/2024 Serious  
Penalty Z: Issued 12/08/2023 $15,625.00 01/29/2024 Serious  

Text For Citation: 01 Item/Group: 005A Hazard:

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Nickel, Cobalt and Total Dust listed in Table Z-1 in excess of the 8-hour Time Weighted Average concentration of 1 mg/m3 for Nickel, 0.1 mg/m3 for Cobalt and 15 mg/m3 for Total Dust: a) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Nickel in that, the employer did not ensure that employees dumping bags of powder were not exposed to Nickel in excess of the permissible exposure limit (PEL) at 1 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 24.46 mg/m3, during 448 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 32 minutes not sampled. b) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Nickel in that, the employer did not ensure that employees involved with cleaning and loading bags of powder were not exposed to Nickel in excess of the permissible exposure limit (PEL) at 1 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 3.73 mg/m3, during 404 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 76 minutes not sampled. c) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Nickel in that, the employer did not ensure that employees dumping bags of powder were not exposed to Nickel in excess of the permissible exposure limit (PEL) at 1 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 11.55 mg/m3, during 446 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 34 minutes not sampled. d) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Nickel in that, the employer did not ensure that employees involved with cleaning and loading bags of powder were not exposed to Nickel in excess of the permissible exposure limit (PEL) at 1 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 32.01 mg/m3, during 439 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 41 minutes not sampled. e) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Cobalt in that, the employer did not ensure that employees dumping bags of powder were not exposed to Cobalt in excess of the permissible exposure limit (PEL) at 0.1 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 4.02 mg/m3, during 448 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 32 minutes not sampled. f) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Cobalt in that, the employer did not ensure that employees involved with cleaning and loading bags of powder were not exposed to Cobalt in excess of the permissible exposure limit (PEL) at 0.1 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 0.63 mg/m3, during 404 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 76 minutes not sampled. g) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Cobalt in that, the employer did not ensure that employees dumping bags of powder were not exposed to Cobalt in excess of the permissible exposure limit (PEL) at 0.1 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 1.90 mg/m3, during 446 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 34 minutes not sampled. h) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Cobalt in that, the employer did not ensure that employees involved with cleaning and loading bags of powder were not exposed to Cobalt in excess of the permissible exposure limit (PEL) at 0.1 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 5.21 mg/m3, during 439 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 41 minutes not sampled. i) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Total Dust in that, the employer did not ensure that employees dumping bags of powder were not exposed to Particulates Not Otherwise Regulated (PNOR) in excess of the permissible exposure limit (PEL) at 15 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 69.07 mg/m3, during 448 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 32 minutes not sampled. j) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Total Dust in that, the employer did not ensure that employees dumping bags of powder were not exposed to Particulates Not Otherwise Regulated (PNOR) in excess of the permissible exposure limit (PEL) at 15 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 21.37 mg/m3, during 446 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 34 minutes not sampled. k) Cathode Powder Mixing Room/ Electrode Department- On or about 6/30/2023, and at times prior, the employer exposed employees to respiratory hazards associated with Total Dust in that, the employer did not ensure that employees involved with cleaning and loading bags of powder were not exposed to Particulates Not Otherwise Regulated (PNOR) in excess of the permissible exposure limit (PEL) at 15 mg/m3 which was calculated as an 8-hour time weighted average (TWA) of 40.24 mg/m3, during 439 minute sampling performed on 6/30/2023. Zero exposure was assumed for the 41 minutes not sampled.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.