Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1643270.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,055.00
Current Penalty: $8,438.50
Issuance Date: 03/23/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/30/2023
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 04/17/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/17/2023 | $8,438.50 | 06/30/2023 | Serious | |
Penalty | Z: Issued | 03/23/2023 | $12,055.00 | 04/11/2023 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):(a) (a) Third Floor Finishing Department: On January 11, 2023, the employer failed to guarding pulleys located less than seven feet near the rear brushes on the Brush Finishing machine.