Violation Detail
Standard Cited: 19100179 G01 V Overhead and gantry cranes.
Inspection Nr: 1559552.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,324.00
Current Penalty: $4,662.00
Issuance Date: 02/17/2022
Nr Instances: 4
Nr Exposed: 1
Abatement Date: 03/16/2022
Gravity: 5
Report ID: 0111100
Contest Date:
Final Order: 03/02/2022
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/02/2022 | $4,662.00 | 03/16/2022 | Serious | |
Penalty | Z: Issued | 02/17/2022 | $9,324.00 | 03/16/2022 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.179(g)(1)(v): Pendant control boxes were not clearly marked for identification of functions: Tank Shop - In the following instances, pendant control boxes were not clearly marked for identification of functions: a) The two-ton Kone Crane in the rebar shop had three buttons with no identification of functions. b) The 25-ton National Crane had a remote control with all of its buttons missing their labels as to the identification of their functions. c) The 25-ton Progressive Crane had a remote control with all of its buttons missing their labels as to the identification of their functions. d) The 25-ton Somatex Crane had a remote control with all of its buttons missing their labels as to the identification of their functions.