Violation Detail
Standard Cited: 19100146 D03 VI Permit-required confined spaces
This violation item has been deleted.
Inspection Nr: 1513598.015
Citation: 01005A
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,653.00
Current Penalty: $0.00
Issuance Date: 07/22/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/17/2021
Gravity: 10
Report ID: 0418100
Contest Date: 08/06/2021
Final Order: 02/06/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 02/06/2024 | $0.00 | 08/17/2021 | Serious | |
| Penalty | C: Contested | 08/24/2021 | $13,653.00 | 08/17/2021 | Serious | |
| Penalty | Z: Issued | 07/22/2021 | $13,653.00 | 08/17/2021 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.146(d)(3)(vi): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices to verify that conditions in a permit space were acceptable for entry throughout the duration of an authorized entry: a - On or about January 28, 2021, at the worksite Foundation Food Group, Inc., located at 2076 Memorial Park Drive, Gainesville, GA, at Plant 4, in the Line 2 and Line 4 liquid nitrogen freezers, employees were exposed to mechanical, thermal and asphyxiation hazards while entering permit required confined space areas within the liquid nitrogen freezers as the employer did not implement verification procedures to ensure acceptable conditions throughout the entry.
Translate