Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1443494.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,747.00
Current Penalty: $2,698.80
Issuance Date: 03/16/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/31/2020
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 04/09/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | 05/06/2020 | $2,698.80 | 07/31/2020 | Serious | |
| Penalty | I: Informal Settlement | 04/09/2020 | $2,698.80 | 05/04/2020 | Serious | |
| Penalty | Z: Issued | 03/16/2020 | $6,747.00 | 05/04/2020 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section. On or about November 07, 2019 the McDonough Re-Saw located in the sawmill department did not have the belt and pulley that provides the power to run the saw guarded.
Translate