Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1424049.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,313.00
Current Penalty: $1,387.80
Issuance Date: 01/16/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/05/2020
Gravity: 1
Report ID: 0420600
Contest Date:
Final Order: 01/31/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/31/2020 | $1,387.80 | 02/05/2020 | Serious | |
| Penalty | Z: Issued | 01/16/2020 | $2,313.00 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. On or about 08/22/2019, at the machine shop, employees were exposed to the ingoing nip point of the drive pulley of the Kysor Johnson horizontal band saw. The guard over the saw's motor drive pulley was removed and not replaced.