Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1391183.015
Citation: 01005A
Citation Type: Serious
Abatement Status:
Initial Penalty: $11,934.00
Current Penalty: $0.00
Issuance Date: 09/26/2019
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 10/30/2019
Gravity: 10
Report ID: 0112600
Contest Date: 11/15/2019
Final Order: 08/19/2022
Related Event Code (REC): A;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/19/2022 | $0.00 | 10/30/2019 | Serious | |
Penalty | C: Contested | 11/19/2019 | $11,934.00 | 10/30/2019 | Serious | |
Penalty | Z: Issued | 09/26/2019 | $11,934.00 | 10/30/2019 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Site: Building 1, at the Coating Line, on the catwalk above the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 a Coating Line Operator did not turn off or shut down the Main Drive using the procedures established for the machine or equipment prior to starting work covered by this subpart. (b) Site: Building 1, at the Coating Line, at the Main Drive on the aisle side, 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 a Coating Line Operator did not turn off or shut down the Main Drive using the procedures established for the machine or equipment prior to starting work covered by this subpart.