Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1379698.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,246.00
Current Penalty: $4,347.40
Issuance Date: 03/07/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 04/23/2019
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 03/29/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/29/2019 | $4,347.40 | 04/23/2019 | Serious | |
Penalty | Z: Issued | 03/07/2019 | $7,246.00 | 04/02/2019 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). On 2/13/19, in the production area on the back of the Take Up machine, employees were exposed to a belt and pulley that was left unguarded.