Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1226735.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,149.00
Current Penalty: $3,566.00
Issuance Date: 09/26/2017
Nr Instances: 2
Nr Exposed: 22
Abatement Date: 10/13/2017
Gravity: 5
Report ID: 0524700
Contest Date: 10/18/2017
Final Order: 09/04/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 09/04/2018 | $3,566.00 | 10/13/2017 | Serious | |
Penalty | C: Contested | 10/20/2017 | $8,149.00 | 10/13/2017 | Serious | |
Penalty | Z: Issued | 09/26/2017 | $8,149.00 | 10/13/2017 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section. a. Ross Casting & Innovation, LLC located in Sidney, Ohio: On or about May 25, 2017, the employer did not ensure the machine specific lockout procedures for the OD Grinder located in Cell #1 clearly specified the techniques to be utilized for the control of the electrical, pneumatic, and gravitational energy. b. Ross Casting & Innovation, LLC located in Sidney, Ohio: On or about May 25, 2017, the employer did not ensure the machine specific lockout procedure for the Auto Saw located in Cell #1 specified the techniques to be utilized for the control of the electric and pneumatic energy.