Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1218667.015
Citation: 01005A
Citation Type: Serious
Abatement Date: 08/11/2017 2
Initial Penalty: $6,338.00
Current Penalty: $4,753.00
Issuance Date: 08/03/2017
Nr Instances: 1
Nr Exposed: 20
Related Event Code (REC): C
Gravity: 5
Report ID: 0523300
Contest Date:
Final Order: 08/31/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/31/2017 | $4,753.00 | 08/11/2017 | Serious | |
Penalty | Z: Issued | 08/03/2017 | $6,338.00 | 08/11/2017 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about May 2, 2017, employees were exposed to machine hazards associated with moving parts when they engaged in cleaning activities. The employer did not ensure that employees implemented energy control application steps prior to allowing them to clean augers controlled by the Dutch Technical Service system. The equipment was not shut down or turned off, isolated, locked out, nor verification of isolation performed prior to engaging in this servicing activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.