Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1178747.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,730.00
Current Penalty: $2,619.00
Issuance Date: 12/01/2016
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 12/20/2016
Gravity: 10
Report ID: 0626600
Contest Date:
Final Order: 12/22/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/22/2016 | $2,619.00 | 12/20/2016 | Serious | |
Penalty | Z: Issued | 12/01/2016 | $8,730.00 | 12/20/2016 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). a. On or about September 20, 2016, and times prior thereto, in the Mill Area, employees were exposed to caught-in hazards when operating a Yates-American A20 Planer without guarding over rotating pulleys. b. On or about September 20, 2016, and times prior thereto, in the east Mill Area, employees were exposed to caught-in hazards when operating an Out feed conveyor without guarding over rotating pulleys.