Violation Detail
Standard Cited: 19261101 G01 I Asbestos
Inspection Nr: 1148713.015
Citation: 01005A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,500.00
Current Penalty: $2,475.00
Issuance Date: 07/29/2016
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 08/18/2016
Related Event Code (REC):
Emphasis:
Substance: 9020
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/18/2016 | $2,475.00 | Serious | ||
Penalty | Z: Issued | 07/29/2016 | $4,500.00 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1926.1101(g)(1)(i): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of vacuum cleaners equipped with high efficiency particulate air (HEPA) filters to collect all debris and dust containing asbestos containing material and presumed asbestos containing material: a.) Facility - On or about May 14, 2016, employees used a shop vacuum to remove construction debris that contained asbestos insulation materials. (25% chrysotile). The employer did not ensure that employees used a High Efficiency Particulate Air (HEPA) vacuum to clean up the asbestos-containing debris. NO ABATEMENT CERTIFICATION REQUIRED