Violation Detail
Standard Cited: 19100134 A02 Respiratory Protection.
Inspection Nr: 1108994.015
Citation: 01005A
Citation Type: Serious
Abatement Date: 06/26/2016 2
Initial Penalty: $7,000.00
Current Penalty: $5,950.00
Issuance Date: 05/24/2016
Nr Instances: 6
Nr Exposed: 10
Related Event Code (REC):
Gravity: 10
Report ID: 0215800
Contest Date: 06/16/2016
Final Order: 11/14/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/14/2016 | $5,950.00 | 06/26/2016 | Serious | |
Penalty | C: Contested | 06/16/2016 | $7,000.00 | 06/26/2016 | Serious | |
Penalty | Z: Issued | 05/24/2016 | $7,000.00 | 06/26/2016 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.134(a)(2): A respirator was not provided by the employer to each employee when such equipment was necessary to protect the health of the employee: a) Strip and Wash Area, on or about 12/2/15: Welders were exposed to chromium metal and its insoluble salts at 2.77 milligrams per cubic meter (mg/m3) or 2.8 times the permissible exposure limit (PEL) of 1 mg/m3 based on the 415 minute sampling period. A zero increment was included for the 65 minutes not sampled. Welders did not wear respirators. b) Strip and Wash Area, on or about 12/2/15: Welders were exposed to nickel at 1.12 milligrams per cubic meter (mg/m3) or 1.12 times the permissible exposure limit (PEL) of 1 mg/m3 based on the 415 minute sampling period. A zero increment was included for the 65 minutes not sampled. Welders did not wear respirators. c) Strip and Wash Area, on or about 12/2/15: Welders were exposed to copper fume at .19 milligrams per cubic meter (mg/m3) or 1.9 times the permissible exposure limit (PEL) of .1 mg/m3 based on the 415 minute sampling period. A zero increment was included for the 65 minutes not sampled. Welders did not wear respirators. d) Strip and Wash Area, on or about 12/2/15: Welders were exposed to iron oxide fume at 77.8 milligrams per cubic meter (mg/m3) or 7.8 times the permissible exposure limit (PEL) of 10 mg/m3 based on the 415 minute sampling period. A zero increment was included for the 65 minutes not sampled. Welders did not wear respirators. e) Strip and Wash Area, on or about 12/2/15: Welders were exposed to total dust at 95.1 milligrams per cubic meter (mg/m3) or 6.3 times the permissible exposure limit (PEL) of 15 mg/m3 based on the 415 minute sampling period. A zero increment was included for the 65 minutes not sampled. Welders did not wear respirators. Abatement documentation must be submitted.