Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 965945.015
Citation: 01005
Citation Type: Serious
Abatement Date: 04/18/2014 2
Initial Penalty: $3,570.00
Current Penalty: $2,677.50
Issuance Date: 04/10/2014
Nr Instances: 3
Nr Exposed: 3
Related Event Code (REC): C
Gravity: 5
Report ID: 0111100
Contest Date:
Final Order: 04/30/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/30/2014 | $2,677.50 | 04/18/2014 | Serious | |
Penalty | Z: Issued | 04/10/2014 | $3,570.00 | 04/18/2014 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)(a): Blender Area - Two inclined belts and a spoked pulley on Mixer #3 located 6 feet above the floor were not guarded.