Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 961504.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,500.00
Current Penalty: $1,750.00
Issuance Date: 04/08/2014
Nr Instances: 2
Nr Exposed: 13
Abatement Date: 06/11/2014
Gravity: 5
Report ID: 0729700
Contest Date:
Final Order: 05/01/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/01/2014 | $1,750.00 | 06/11/2014 | Serious | |
| Penalty | Z: Issued | 04/08/2014 | $3,500.00 | 06/11/2014 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:. Employees working drilling rig #6, SEC 31, TWP 14, R 31, 1370 fnl, 1130 fsl, Oakley, KS were exposed to caught in hazards in that rotating horizontal shafting was not fully enclosed on the following equipment: a) mud mixer motor; 2 inch section located 22 inches from the ground. b) water pump; 2 inch section located 15 inches from the floor.