Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 955136.015
Citation: 01005
Citation Type: Serious
Abatement Date: 07/29/2014 2
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 06/09/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 06/20/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/20/2014 | $7,000.00 | 07/29/2014 | Serious | |
Penalty | Z: Issued | 06/09/2014 | $7,000.00 | 07/29/2014 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: Location: Shucking Machine Steam Valves Employee did not use a lockout device while cleaning the Shucking Machine.