Violation Detail
Standard Cited: 19100107 D12 Spray finishing using flammable and combustible materials.
Inspection Nr: 945904.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,500.00
Current Penalty: $2,100.00
Issuance Date: 05/01/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/18/2014
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 05/21/2014
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/21/2014 | $2,100.00 | 06/18/2014 | Serious | |
Penalty | Z: Issued | 05/01/2014 | $3,500.00 | 06/18/2014 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.107(d)(12): Freshly sprayed articles were dried in spaces that were not provided with adequate ventilation to prevent the formation of explosive vapors. When adequate and reliable ventilation was not provided such drying spaces were considered a spraying area, for the purposes of this standard. PAINT SPRAY BOOTH: On or about November 4, 2013, freshly sprayed articles were moved out of the paint spray booth to dry. Parts of washers and dryers that had been painted were hanging on multiple racks outside the spray booth. A live wall-mounted receptacle was located in close proximity to the racks of freshly sprayed pieces.