Violation Detail
Standard Cited: 19100272 L01 Grain handling facilities.
Inspection Nr: 907832.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,380.00
Current Penalty: $1,428.00
Issuance Date: 06/26/2013
Nr Instances: 2
Nr Exposed: 9
Abatement Date: 08/08/2013
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 07/17/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/17/2013 | $1,428.00 | 08/08/2013 | Serious | |
| Penalty | Z: Issued | 06/26/2013 | $2,380.00 | 07/31/2013 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.272(l)(1): All fabric dust filter collectors which are a part of a pneumatic dust collection system shall be equipped with a monitoring device that will indicate a pressure drop across the surface of the filter: a. Outside at the front of the plant, the Magnehelic differential pressure gage for the Honeyville dust collector (S/N: 990265) which services the polishers was not connected properly to indicate a pressure drop across the surface of the filter. b. Outside at the front of the plant, the Magnehelic differential pressure gage for the Honeyville dust collector (S/N: 990261) which services the main cleaner was not connected properly to indicate a pressure drop across the surface of the filter.
Translate