Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 904339.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,300.00
Current Penalty: $4,410.00
Issuance Date: 10/30/2013
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/20/2013
Gravity: 10
Report ID: 0626000
Contest Date:
Final Order: 12/03/2013
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/03/2013 | $4,410.00 | 12/20/2013 | Serious | |
| Penalty | Z: Issued | 10/30/2013 | $6,300.00 | 12/20/2013 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, were not protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires: At the north end of the holding tanks, the two charge pumps were not provided with full guarding of the horizontal rotating drive shaft.