Violation Detail
Standard Cited: 19260502 A02 Fall protection systems criteria and practices.
Inspection Nr: 902713.015
Citation: 01005
Citation Type: Serious
Abatement Date: 07/05/2013 2
Initial Penalty: $3,080.00
Current Penalty: $1,232.00
Issuance Date: 06/26/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0418200
Contest Date:
Final Order: 07/10/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/10/2013 | $1,232.00 | 07/05/2013 | Serious | |
Penalty | Z: Issued | 06/26/2013 | $3,080.00 | 07/05/2013 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1926.502(a)(2): The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection. (a) Back side, new townhome construction located at 523 Micayne Circle, Smyrna, GA 30082: Employee was exposed to falls while installing cornice boards on a pump jack scaffold platform at heights of approximately 24-feet, 6-inches with a personal fall protection system which included a makeshift life-line, missing lanyard, missing rope grab and an anchor point with metal or similar connections.