Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 895044.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,800.00
Current Penalty: $1,400.00
Issuance Date: 04/12/2013
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 04/22/2013
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 05/06/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/06/2013 | $1,400.00 | 04/22/2013 | Serious | |
| Penalty | Z: Issued | 04/12/2013 | $2,800.00 | 04/22/2013 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: On or about March 12, 2013, at the job site, the employer did not ensure that excavation was properly shored, sloped or otherwise protected to prevent a cave-in hazard. Employees are installing a French drain in an excavation that is approximately nine and a half feet deep and 60 feet long trench that is not adequately protected from cave-in hazards. The spoil pile is stored too close to the edge of the excavation, and employees are not wearing a hard hats. This condition exposed employees to crush-by hazards.
Translate