Violation Detail
Standard Cited: 19100253 B04 III Oxygen-fuel gas welding and cutting.
Inspection Nr: 668198.015
Citation: 01005
Citation Type: Serious
Abatement Date: 04/05/2013 2
Initial Penalty: $4,000.00
Current Penalty: $2,125.00
Issuance Date: 02/19/2013
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0419700
Contest Date:
Final Order: 03/06/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/06/2013 | $2,125.00 | 04/05/2013 | Serious | |
Penalty | Z: Issued | 02/19/2013 | $4,000.00 | 04/05/2013 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: a. On or about October 1, 2012, on the south side of the welding building, the oxygen cylinders were not separated from the acetylene cylinders, exposing employees to an explosive hazard.