Standard Cited: 19100119 J04 III Process safety management of highly hazardous chemicals.

This violation item has been deleted.

Inspection Nr: 465418.015

Citation: 01005

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $5,000.00

Current Penalty: $0.00

Issuance Date: 09/28/2012

Nr Instances: 1

Nr Exposed: 6

Abatement Date: 11/13/2012

Gravity: 5

Report ID: 0625400

Contest Date:

Final Order: 10/22/2012

Related Event Code (REC):

Emphasis:

Substance: 0170


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 10/22/2012 $0.00 11/13/2012 Serious  
Penalty Z: Issued 09/28/2012 $5,000.00 11/13/2012 Serious  

Text For Citation: 01 Item/Group: 005 Hazard:

29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment were not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience. On or about 12 June 2012, and at times prior thereto, the employer did not conduct inspections and testing of process equipment with a frequency consistent with the applicable manufacturers' recommendations and good engineering practices. The employer hired an outside source, Process Compliance Inc. or PCI, to conduct a full mechanical integrity inspection and testing of the process equipment, which was accomplished in January 2012. PCI issued a full report to the employer with recommendations on priority items. However, the employer could not produce any documentation on prior inspection and testing of the process equipment, since the ammonia refrigeration system was installed in 1999. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure the frequency of inspections and testing of process equipment is consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.