Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1819689.015
Citation: 01005
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $14,187.00
Current Penalty: $0.00
Issuance Date: 08/15/2025
Nr Instances: 1
Nr Exposed: 42
Abatement Date:
Gravity: 5
Report ID: 0625500
Contest Date: 09/12/2025
Final Order: 05/06/2026
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/06/2026 | $0.00 | Serious | ||
| Penalty | C: Contested | 09/12/2025 | $14,187.00 | Serious | ||
| Penalty | Z: Issued | 08/15/2025 | $14,187.00 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(e)(1)(i):Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): On or about April 21, 2025, at bread oven infeed conveyor (P12), employees worked near the conveyor belt system that was not guarded.