Violation Detail
Standard Cited: 19100134 A01 Respiratory Protection.
Inspection Nr: 1771942.015
Citation: 01005
Citation Type: Serious
Abatement Status:
Initial Penalty: $16,550.00
Current Penalty: $16,550.00
Issuance Date: 02/06/2025
Nr Instances: 11
Nr Exposed: 1
Abatement Date: 03/07/2025
Gravity: 10
Report ID: 0627510
Contest Date: 03/04/2025
Final Order:
Related Event Code (REC):
Emphasis:
Substance: 0640
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 03/07/2025 | $16,550.00 | 03/07/2025 | Serious | |
Penalty | Z: Issued | 02/06/2025 | $16,550.00 | 03/07/2025 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.134(a)(1): Atmospheric contamination was not prevented through the use of engineering controls, such as, but not limited to enclosure or confinement of the operation, general and local ventilation, or substitution of less toxic materials: On or about August 9, 2024 employees in the CIP room were not provided effective engineering controls, such as open doors, exhaust fans, or other measures, when participating in emergency response to a chlorine gas exposure.