Standard Cited: 19100179 K02 Overhead and gantry cranes.
Inspection Nr: 1744068.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $12,098.25
Issuance Date: 10/23/2024
Nr Instances: 4
Nr Exposed: 149
Abatement Date: 06/30/2025
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 11/19/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 05/16/2025 | $12,098.25 | 06/30/2025 | Serious | |
Penalty | I: Informal Settlement | 11/19/2024 | $12,098.25 | 11/19/2024 | Serious | |
Penalty | Z: Issued | 10/23/2024 | $16,131.00 | 11/19/2024 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.179(k)(2):Rated load test reports were not placed on file where they were readily available to appointed personnel: (a) Core Stacking Area: on or about and at times prior to April 24, 2024, employees use the 35/5-ton Shaw Box crane S/N 37787 to move transformers weighing up to 15-tons. The load testing reports were not available when requested. (b) HVA Area: on or about and at times prior to April 24, 2024, employees use the 35-ton Cyclops crane S/N 1302 to move transformers weighing up to 15-tons. The load testing reports were not available when requested. (c) Metal Fabrication Area: on or about and at times prior to April 24, 2024, employees use the 15-ton Cyclops crane S/N 1297 to move transformers weighing up to 15-tons. The load testing reports were not available when requested. (d) Metal Fabrication Area: on or about and at times prior to April 24, 2024, employees use the 15/5-ton Shaw Box crane S/N 38783 to move transformers weighing up to 15-tons. The load testing reports were not available when requested.