Violation Detail
Standard Cited: 19100272 L02 Grain handling facilities.
Inspection Nr: 1742763.015
Citation: 01005
Citation Type: Serious
Abatement Status:
Initial Penalty: $11,292.00
Current Penalty: $4,516.80
Issuance Date: 09/27/2024
Nr Instances: 2
Nr Exposed: 31
Abatement Date: 12/19/2025
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 10/25/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/25/2024 | $4,516.80 | 12/19/2025 | Serious | |
Penalty | Z: Issued | 09/27/2024 | $11,292.00 | 02/18/2025 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.272(l)(2): Filter collectors installed after March 30, 1988 were not: (i) located outside of the facility; or (ii) located in an area inside the facility protected by an explosion suppression system; or (iii) located in an area inside the facility that is separated from other areas of the facility by construction having at least one hour fire-resistance rating, and which is adjacent to an exterior wall and vented to the outside: (a) South Plant - New Warehouse, Barley Room Dust Collector; On April 19, 2024, the dust collector was located inside the warehouse and returned air to the barley room sacking area. The dust collector was not protected by an explosion suppression system, it was not separated from other areas of the facility by construction having at least a one hour fire-resistance rating, and it was not vented to the outside. (b) South Plant - Cleaning Plant, 3rd floor, Torit (model TD3060-O.B. S/N BB5981) Dust Collector; On April 19, 2024, the dust collector was located inside and returned air to the 3rd floor. The dust collector was not protected by an explosion suppression system, it was not separated from other areas of the facility by construction having at least a one hour fire-resistance rating, and it was not vented to the outside.