Violation Detail
Standard Cited: 19100333 C03 I A 1 Selection and use of work practices
Inspection Nr: 1742712.015
Citation: 01005
Citation Type: Serious
Abatement Date: 10/07/2024 2
Initial Penalty: $4,839.00
Current Penalty: $4,839.00
Issuance Date: 10/01/2024
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0214700
Contest Date:
Final Order: 10/28/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 10/01/2024 | $4,839.00 | 10/07/2024 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location between the person and longest conductive object he or she may contact, cannot be within 10 feet of any unguarded, energized overhead line: a) Worksite: 15 Salem Way, Glen Head, NY 11545 - Employee was removing branches while working in a tree directly next to energized overhead power lines. The employee was electrocuted when he came in contact with 7620 volts; on or about 04/19/24. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19