Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1721548.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $6,775.20
Issuance Date: 05/22/2024
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 06/21/2024
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 06/18/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/18/2024 | $6,775.20 | 06/21/2024 | Serious | |
Penalty | Z: Issued | 05/22/2024 | $11,292.00 | 06/21/2024 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: ( Reference: 29 CFR 1910. 213(a)(9) ) (a) Crowder area; On or about January 17, 2024, and dates prior, in-going nip-points between chains and sprockets on the inclined crowder infeed conveyor were not guarded. (b) Pendu scissors table area; On or about January 17, 2024, and dates prior, in-going nip-points between chains and sprockets on the Pendu conveyors were not guarded along the front or back sides.