Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1667646.015
Citation: 01005
Citation Type: Serious
Abatement Date: 11/15/2023 2
Initial Penalty: $15,625.00
Current Penalty: $11,000.00
Issuance Date: 09/28/2023
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC): A
Gravity: 10
Report ID: 0317500
Contest Date:
Final Order: 10/17/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/17/2023 | $11,000.00 | 11/15/2023 | Serious | |
Penalty | Z: Issued | 09/28/2023 | $15,625.00 | 10/25/2023 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) Facility: On or about May 1, 2023, and at times prior thereto "affected" employee(s) were exposed to hazardous energy including but not limited to pneumatic 800 psi, while attempting to repair a Pomacon machine (10k/72") without training on the purpose and use of lockout/tagout.