Violation Detail
Standard Cited: 19100305 G02 III Wiring methods, components, and equipment for general use.
Inspection Nr: 1629931.015
Citation: 01005
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,366.00
Current Penalty: $4,419.60
Issuance Date: 04/19/2023
Nr Instances: 1
Nr Exposed: 50
Abatement Date:
Gravity: 1
Report ID: 0627100
Contest Date:
Final Order: 05/04/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/04/2023 | $4,419.60 | Serious | ||
Penalty | Z: Issued | 04/19/2023 | $7,366.00 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) On or about October 20, 2022, in the production area, employees were using a DeWalt circular saw that was receiving power from a flexible cord that had the outer insulation pulled from the attachment plug, exposing the insulated conductors.