Violation Detail
Standard Cited: 19100252 C06 II General requirements.
Inspection Nr: 1608415.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,287.00
Current Penalty: $8,287.00
Issuance Date: 12/06/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/09/2023
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 01/05/2023
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 12/06/2022 | $8,287.00 | 01/09/2023 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.252(c)(6)(ii): Indoors, welding or cutting involving zinc-bearing base or filler metals coated with zinc-bearing materials was not done in accordance with 29 CFR 1910.252(c)(3): (a) Thoutt Bros. Concrete Contractors Inc. at 5460 Tennyson St. in Denver, CO: On or about July 18, 2022, and at times prior, employees were exposed to respiratory hazards when the employer did not provide local exhaust ventilation in the fabrication shop for employees welding metal coated with zinc-bearing materials.