Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1604305.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $0.00
Issuance Date: 10/28/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 11/25/2022
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 11/22/2022
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/22/2022 | $0.00 | 11/25/2022 | Serious | |
Penalty | Z: Issued | 10/28/2022 | $14,502.00 | 11/25/2022 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section. a) On or about June 17, 2022, on the tumbler feed belt that was located less than 7 feet from floor level, the silver plate was not flush against the belt to prevent an ingoing nip point.