Violation Detail
Standard Cited: 19261053 B05 I Ladders.
Inspection Nr: 1599749.015
Citation: 01005
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $14,502.00
Current Penalty: $10,151.00
Issuance Date: 10/21/2022
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 11/18/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/18/2022 | $10,151.00 | Serious | ||
Penalty | Z: Issued | 10/21/2022 | $14,502.00 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1926.1053(b)(5)(i):Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). a) On or about 04/21/2022, at 4830 NW 65 Avenue Fort Lauderdale FL 33319, employees engaged in housekeeping activities, using a Werner 28-ft Type 1A non-conductive fiberglass extension ladder to access the second floor, were exposed to fall hazards. The ladder was set up where the horizontal distance (6.3 feet) exceeded one-quarter of the working length of the ladder (12.25 feet).