Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1581251.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,151.00
Current Penalty: $6,691.68
Issuance Date: 06/24/2022
Nr Instances: 42
Nr Exposed: 12
Abatement Date: 03/13/2023
Gravity: 10
Report ID: 0112000
Contest Date:
Final Order: 07/25/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | 12/12/2022 | $6,691.68 | 03/13/2023 | Serious | |
| Penalty | P: Petition to Mod Abatement | 10/05/2022 | $6,691.68 | 12/12/2022 | Serious | |
| Penalty | I: Informal Settlement | 07/25/2022 | $6,691.68 | 10/11/2022 | Serious | |
| Penalty | Z: Issued | 06/24/2022 | $10,151.00 | 08/11/2022 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts, flying chips and the unused portion of a blade: Production Area: On, or about, May 12, 2022, the following machines were not provided with adequate safeguarding: A. H1, Makino: The interlock provided for the access door was bypassed. B. H2, Makino: The interlock provided for the access door was bypassed. C. H4, Makino: The interlock provided for the access door was bypassed. D. V2, Mori Seiki: The interlock provided for the access door was bypassed. E. H5, Mori Seiki: The interlock provided for the access door was not connected. F. H7, Yasda: The interlock provided for the access door was bypassed. G. H8, Okuma: The interlock provided for the access door was bypassed. H. V7, Fadal: The access door was not provided with an interlock. I. H9, Kiwa: The interlock provided for the access door was bypassed. J. H10, Kiwa: The interlock provided for the access door was bypassed. K. H11, Makino: The access door was not provided with an interlock. L. H12, Makino: The door interlock mechanism for the access door appeared to be missing. M. V9, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. N. V10, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. O. V11, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. P. V12, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. Q. V13, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. R. V14, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. S. V15, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. T. V17, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. U. V18, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. V. V20, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. W. V21, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. X. V22, Fadal: The machine appeared to be provided with proximity switch on the access door that was not functional. Y. V6, Matsuura: The access door was provided with an interlock, but it was not programmed into the machine and was not operational. Z. H28, Mori Seiki: The interlock provided for the access door was bypassed. AA. H29, Mori Seiki: The interlock provided for the access door was bypassed. BB. H22, Mori Seiki: The interlock provided for the access door was bypassed. CC. H23, Mori Seiki: The interlock provided for the access door was bypassed. DD. H24, Mori Seiki: The interlock provided for the access door was bypassed. EE. H25, Mori Seiki: The interlock provided for the access door was bypassed. FF. H26, Mori Seiki: The interlock provided for the access door was bypassed. GG. H27, Mori Seiki: The interlock provided for the access door was bypassed. HH. V26, Fadal: The access door was not provided with an interlock. II. H35, Doosan: The interlock provided for the access door was bypassed. JJ. H36, Doosan: The interlock provided for the access door was bypassed. KK. H38, Matsuura: The interlock provided for the access door was bypassed and the auger-type chip conveyor could run continuously with the access door open. LL. H39, Okuma: The interlock provided for the access door was bypassed. MM. Amada horizontal band saw, serial number 95350401: The auger-type chip collector was not provided with a guard. NN. Kalamazoo horizontal band saw, serial number P14T904: A guard was not provided for the unused portion of the saw blade. OO. Johnson horizontal band saw, serial number J-15468: A guard was not provided for the unused portion of the saw blade. PP. L21, Slant 50: The window provided in the access door was broken.
Translate