Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1558351.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,431.00
Current Penalty: $9,060.68
Issuance Date: 03/23/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 04/18/2022
Gravity: 5
Report ID: 0213400
Contest Date:
Final Order: 04/14/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/14/2022 | $9,060.68 | 04/18/2022 | Serious | |
Penalty | Z: Issued | 03/23/2022 | $12,431.00 | 04/18/2022 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A) Douglas Cartoner located at Plant 8 Multilane - 1090 Springfield Rd., Union, NJ 07083 The adhesive dispensing applicators do not have a point of operation guard to prevent operator(s) from placing their fingers and hands into the hot surfaces when employees are cleaning and/or servicing the machine. This exposed employees to burn hazards. Exposure occurred on or about 12/08/2021