Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 1509280.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $11,782.00
Issuance Date: 07/08/2021
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 07/27/2021
Gravity: 10
Report ID: 0523400
Contest Date: 07/29/2021
Final Order: 07/14/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/14/2022 | $11,782.00 | 07/27/2021 | Serious | |
Penalty | C: Contested | 08/03/2021 | $13,653.00 | 07/27/2021 | Serious | |
Penalty | Z: Issued | 07/08/2021 | $13,653.00 | 07/27/2021 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.179(j)(2): The items listed in 29 CFR 1910.179(j)(2)(i)-(vii) were not inspected for defects at the frequent inspection intervals defined in 29 CFR 1910.179 (j)(1)(ii) or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: (a) On or about January 11, 2021, the employer did not conduct frequent (daily to monthly) inspections of the overhead crane located in the assembly/paint area. The crane is used on a daily basis to remove and place enclosures, tanks and basins made of steel. The pendant control box was broken and missing a large portion of the plastic housing and the pendant controls were not labeled.