Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1473255.015
Citation: 01005
Citation Type: Serious
Abatement Date: 11/04/2020 2
Initial Penalty: $12,145.00
Current Penalty: $8,600.00
Issuance Date: 10/23/2020
Nr Instances: 1
Nr Exposed: 11
Related Event Code (REC): A
Gravity: 10
Report ID: 0215000
Contest Date: 11/18/2020
Final Order: 03/04/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/04/2021 | $8,600.00 | 11/04/2020 | Serious | |
Penalty | C: Contested | 01/06/2021 | $12,145.00 | 11/04/2020 | Serious | |
Penalty | Z: Issued | 10/23/2020 | $12,145.00 | 11/04/2020 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. 3432 Atlantic Ave, Brooklyn, NY. On or about 4/25/2020, a) The employer developed an energy control program, which included a generic lockout/tagout procedure for servicing machineries. Employees were not trained on the purpose, function, and procedure of an energy control program.