Violation Detail
Standard Cited: 19100179 G02 I Overhead and gantry cranes.
Inspection Nr: 1466696.015
Citation: 01005
Citation Type: Serious
Abatement Date: 07/01/2020 2
Initial Penalty: $10,409.00
Current Penalty: $10,409.00
Issuance Date: 05/27/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 06/22/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 05/27/2020 | $10,409.00 | 07/01/2020 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.179(g)(2)(i): Electrical equipment was not so located or enclosed that live parts would not be exposed to accidental contact under normal operating conditions: a) On March 2, 2020, and times prior to, where there was no cover on the junction box in the cab of the overhead crane 995 in Building 9.