Violation Detail
Standard Cited: 19101200 F06 II Hazard Communication.
Inspection Nr: 1459787.015
Citation: 01005
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $7,711.00
Current Penalty: $7,711.00
Issuance Date: 07/22/2020
Nr Instances: 6
Nr Exposed: 25
Abatement Date: 08/24/2020
Gravity:
Report ID: 0728500
Contest Date:
Final Order: 08/17/2020
Related Event Code (REC):
Emphasis:
Substance: 0020
Substance: 1860
Substance: 1912
Substance: 2310
Substance: A613
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/17/2020 | $7,711.00 | 08/24/2020 | Other | |
| Penalty | Z: Issued | 07/22/2020 | $7,711.00 | 08/17/2020 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: At a worksite located at 17562 Gum Rd, Carthage, MO: Employees were exposed to toxic and/or hazardous substances. The employer failed to ensure that all containers at the facility were properly labeled as to its contents. c) This was demonstrated on January 29, 2020 when a large hopper (U-005) outside of Chub Emulsion was missing an identifying label. The contents of the hopper were identified as Ammonium Nitrate. d) This was demonstrated on January 29, 2020 when a large tanks (TK-1100) located in the Oxidizer Tank Farm area had a label that was no longer identifiable. The contents of the tank were identified as Oxidizer Storage (Raw AN & Oxidizer). f) This was demonstrated on January 29, 2020 when a large tanks (TK-400) located in the Oxidizer Tank Farm area had a label that was no longer identifiable. The contents of the tank were identified as SN Reactor (46% HNO3, Sodium Nitrate Urea, Sodium Carbonate, & Raw AN).
Translate