Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1455338.015
Citation: 01005
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,453.00
Current Penalty: $275.00
Issuance Date: 03/03/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0214500
Contest Date: 03/10/2021
Final Order: 09/20/2021
Related Event Code (REC): I
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/20/2021 | $275.00 | Serious | ||
Penalty | C: Contested | 08/23/2021 | $4,453.00 | Serious | ||
Penalty | Z: Issued | 03/03/2020 | $4,453.00 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a- Building Exterior (Entrance & Rear): Employees engaged in siding activities were exposed to fall hazards as a means of scaffold access and egress had not been utilized exposing workers to fall hazards of approximately 16ft to the concrete below. Condition noted or about 01/13/2020.