Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1391686.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,031.00
Current Penalty: $1,818.60
Issuance Date: 06/04/2019
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 06/14/2019
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 07/12/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/12/2019 | $1,818.60 | 06/14/2019 | Serious | |
| Penalty | Z: Issued | 06/04/2019 | $3,031.00 | 06/14/2019 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(f)(1): Gears were not guarded by a complete enclosure: a) On or about 4/18/2019, In the facility: The Columbia Machinery Press Brake had a portion of its drive gear that was not enclosed by a guard or cover. Abatement certification is required for this item.