Violation Detail
Standard Cited: 19100147 C06 I B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1364702.015
Citation: 01005
Citation Type: Serious
Abatement Date: 06/19/2019 2
Initial Penalty: $13,260.00
Current Penalty: $0.00
Issuance Date: 05/23/2019
Nr Instances: 1
Nr Exposed: 40
Related Event Code (REC):
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 06/17/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/17/2019 | $0.00 | 06/19/2019 | Serious | |
Penalty | Z: Issued | 05/23/2019 | $13,260.00 | 06/19/2019 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified: (a) On or about November 26, 2018, the employer failed to perform a complete inspection and review of the energy control procedures for approximately 60 machines, to include a shutdown of the machines during servicing or maintenance, in order to find any deficiencies with the energy control procedures.