Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1362345.015
Citation: 01005
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $6,630.00
Current Penalty: $6,200.00
Issuance Date: 05/02/2019
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 05/14/2019
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 05/24/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/24/2019 | $6,200.00 | 05/14/2019 | Serious | |
Penalty | Z: Issued | 05/02/2019 | $6,630.00 | 05/14/2019 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: (a) Paint line loading / unloading area - On or about 11/16/18, a pedestal mounted floor fan had a damaged guard with openings greater that 1/2 inch in its least dimension, exposing employees to amputation hazards.